Description
- Requires 3” (7,62 cm) diameter chimney parts.
- A minimum chimney length of 4ft (1.2 m) and a maximum of 8ft (2.4 m) is required, 6ft (1,8 m) straight run with no elbows works best.
- We always recommend a barometric damper; to absorb wind fall and to stimulate draft. • Barometric Damper Installation & Operation.
- Permanent fresh air vent needed in direct area of the unit.
- Provides radiant heat which will dry out moisture inside the vessel/cabin.
- Almost identical model to the Newport bulkhead model but the Alaska is a floor mounted heater.
- In sailboat installations, this unit must face fore or aft, if facing port or starboard is desired, the valve would need to be mounted to the side of the unit so the gravity fed valve won’t starve the burner on heels up to 15 degrees.
- 12v draft assist fan included (5 Amp) (can be converted to 24v and 32v). Used for startup and draft assistance on high fire and low draft.
- Valve is calibrated for diesel but can be re-calibrated for kerosene or stove oil.
- Hot water coil for 19-38 litres or 76-140 litres can be installed for water heating. 1-turn or 4-turn coil.