Description
- Requires 4” (10.16 cm) diameter chimney components (all other ovens require 5” / 12.7 cm)
- Minimum chimney height required is 4 ft (1.2 m), with a maximum of 6 ft (1.8 m); a straight vertical run of 4.6 ft (1.4 m) with no elbows provides optimal performance
- A barometric damper is always recommended to absorb wind downdraft and improve draft stability • Barometric Damper Installation & Operation.
- A permanent fresh air vent is required in the area where the unit is installed
- Produces a dry heat, helping to remove moisture inside the vessel
- In sailboat installations, the unit must face port or starboard so the gravity-fed valve will not starve the burner at heel angles up to 15 degrees. Facing fore or aft is currently not supported
- Includes a 12 V draft assist fan (convertible to 24 V), used for startup and draft assistance at high fire
- Fuel valve is calibrated for diesel, but can be re-calibrated for kerosene or stove oil
- A 1-turn hot water coil for 19-38 litres of water can be installed for water heating)